Marrs Construction Inc Licenses
Arizona ROC: B1 – 292010
B-1 GENERAL COMMERCIAL CONTRACTOR
This classification allows the licensee to construct, alter, and repair in connection with any structure built, being built, or to
be built for the support, shelter, and enclosure of persons, animals, or movable property of any kind. This scope includes
the supervision of all or any part of the above and includes the management, or direct or indirect supervision of any work
performed.
Arizona ROC: KA - 319690
KA- DUAL ENGINEERING
This classification allows the scope of work permitted by the commercial A- General Engineering and the B-4 General
Residential Engineering licenses.
Also included are the scopes of work allowed by the A-4 through A-19.
A- GENERAL ENGINEERING
This classification allows the licensee to construct or repair:
1. Fixed works
2. Streets
3. Roads
4. Power and utility plants
5. Dams
6. Hydroelectric plants
7. Sewage and waste disposal plants
8. Bridges
9. Tunnels
10.Overpasses
11. Public parks
12. Public Right-of-Ways
A-4 DRILLING
This classification allows the licensee to drill, including horizontal and vertical drilling or boring, constructing, deepening,
repairing, or abandoning wells; exploring for water, gas, and oil; and constructing dry wells, and monitor wells. Also included
is the erection of rigs, derricks and related substructures, and installation, service and repair of pumps and pumping
equipment.
A-5 EXCAVATING, GRADING AND OIL SURFACING
This classification allows the licensee to apply oil surfacing or other similar products; place shoring, casing, geotextiles or
liners; and perform incidental blasting or drilling as required for the licensee to move, alter, or repair earthen materials by:
1. Digging
2. Trenching
3. Grading
4. Horizontal boring
5. Compacting
6. Filling
This license does not allow the licensee to excavate for water, gas or oil wells.
A-7 PIERS AND FOUNDATIONS
This classification allows the licensee to install piers and foundations using concrete, rebar, post tension and other
materials common to the industry. Includes pile driving, excavation, forming and other techniques and equipment common
to the industry.
A-9 SWIMMING POOLS
This classification allows the licensee to construct, service, and repair of swimming pools and spas, including
water and gas service lines from point of service to pool equipment, wiring from pool equipment to first readily
accessible disconnect, pool piping, fittings, backflow prevention devices, waste lines, and other integral parts of
a swimming pool or spa.
Also included is the installation of swimming pool accessories, covers, safety devices, and fencing for protective purposes,
if in the original contract.
A-11 STEEL AND ALUMINUM ERECTION
This classification allows the licensee to install and repair architectural and structural steel and aluminum materials common
to the industry. This classification also includes reinforcing steel and field layout, cutting, assembly, and erection by welding,
bolting, wire tying or riveting.
A-12 SEWERS, DRAINS AND PIPE LAYING
This classification allows the licensee to install and repair any project involving sewer access holes, the laying of pipe for
storm drains, water and gas lines, irrigation, and sewers. Includes connecting sewer collector lines to building drains and
the installation of septic tanks, leach lines, dry wells, all necessary connections, liners and related excavating and
backfilling.
A-14 ASPHALT PAVING
This classification allows the licensee to install asphalt paving, and all related fine grading on streets, highways, driveways,
parking lots, tennis courts, running tracks, play areas, and gas station driveways and areas, using materials and accessories
common to the industry. Only permitted as it pertains to the larger scope of work, the classification also permits excavation
and grading only for height adjustment of existing sewer access holes, storm drains, water valves, sewer cleanouts, and
drain gates. Also included is the scope of work allowed by the A-15 Seal Coating Classification.
A-15 SEAL COATING
This classification allows the licensee to apply seal coating to asphalt paving surfaces. This classification also allows repair of
surface cracks and application of painted marking symbols.
A-16 WATERWORKS
This classification allows the licensee to perform all work necessary for the production and distribution of water including
drilling well, setting casing and pump, related electrical work, related concrete work, excavation, piping for storage and
distribution, storage tanks, related fencing, purification and chlorination equipment.
A-17 ELECTRICAL AND TRANSMISSION LINES
This classification allows the licensee to install, alter, and repair transmission lines on public Right-of-Ways, including
erection of poles, guying systems, tower line erection, cellular and communication towers, street lighting of all voltages,
and all underground systems including ducts for signal, communication, and similar installations.
This classification also allows the licensee to install transformers, circuit breakers, capacitors, primary metering
devices and other related equipment of all commercial electrical construction.
A-19 SWIMMING POOLS, INCLUDING SOLAR
This classification allows the licensee to perform the same scope of work permitted by the A-9 but also includes installation
and repair of solar heating devices..
B-4 GENERAL RESIDENTIAL ENGINEERING CONTRACTOR
This classification allows the licensee to construct and repair appurtenances to residential structures. Work related to
electrical, plumbing, air conditioning systems, boilers, and water wells must be subcontracted to an appropriately licensed
contractor. This scope includes the CR-21, B- 5 and all B-4R subclassifications.
C-21 HARDSCAPING AND IRRIGATION SYSTEMS
This classification allows the licensee to install, alter, and repair:
1. Non-loadbearing concrete
2. Uncovered patios, walkways, driveways made of brick, stone, pavers or gravel
3. Wooden decks no higher than 29 inches above finish grade
4. Decorative garden walls up to six feet from finish grade
5. Fences and screens up to six feet from finish grade
6. Retaining walls up to three feet from the finish grade of the lower elevation
7. Free standing fire pits, fireplaces, or barbeques – electric, plumbing, and gas must be subcontracted to a properly licensed
contractor
8. Low voltage landscape lighting
9. Water features that are not attached to swimming pools; including any necessary: electrical wiring of 120 volts or
less, connection to potable water lines, backflow prevention devices, hose bibs, excavating, trenching, boring,
backfilling, or grading
10. Irrigation systems, including any necessary: electrical wiring of 120 volts or less, connection to potable water
lines, backflow prevention devices, hose bibs, excavating, trenching, boring, backfilling, or grading
B-5 GENERAL SWIMMING POOL CONTRACTOR
This classification allows the licensee to construct and repair swimming pools and spas. Installation of code required pool
barriers around the swimming pool or spa and installation of utilities from the point of service to the pool equipment.